Critec Range
The Critec surge protection range consists of a wide variety of surge protectors, diverters, arresters, suppressors, filters and a number of other protection devices which are used in power and data lines.
The Critec range is developed and designed using a 6 point plan of protection agaisnt direct spikes and surges for power and data lines, making it ideal for use in the telecommunications industry.
Below is a table outlining specifications for the Novaris surge protection range. For more detailed specifications, download the Critec Surge Protection Range document.
Product Technical Description
Imax = Maximum Discharge Current (8/20µs) [unless stated otherwise]
Up = Voltage Protection Level - @ 3kA (8/20µs) [unless stated otherwise]
Uc = Maximum continuous operating voltage
Iimp= Maximum impulse current (10/350µs) [unless stated otherwise]
Iload=Maximum load current
|
Model
|
Imax / Iimp / Iline
|
Up
|
Uc
|
Phase/Pole
|
|
SEP400 – Service Entrance Premium
|
100kA
|
400 – 1560V
|
170 – 400V
|
3 Phase
|
|
SES200 – Service Entrance Standard
|
800 – 100kA
|
400 – 2000V
|
170 – 528V
|
1 & 3 Phase
|
|
SES65 – Service Entrance Standard
|
65kA
|
400 – 520V
|
150V
|
1 Phase
|
|
TDS MT – Transient Discriminating MOVTEC
|
200kA (MT)
40kA L-N & L-G (MTU)
20kA N-G (MTU)
|
330 – 1500V
|
170 – 528V
|
|
|
TDX 150 Series – Transient Discriminating Panel Protectors
|
75kA
|
400 – 1640V
|
170 – 830V
|
1 & 3 Phase
|
|
TDX 100 Series
|
50kA
|
400 – 1400V
|
70 – 830V
|
1 & 3 Phase
|
|
TDX 50 Series
|
25kA
|
400 – 1660V
|
10 – 830V
|
1 & 3 Phase
|
|
TDS MPM – TD Protection Module
|
100 – 130kA
|
0.75 – 2.3kV
|
400/692V
|
3 Phase
|
|
TSG SRF – Triggered Spark Gap Surge Reduction Filters
|
130kA / Iimp=50kA
|
262 – 413V
|
175V
|
1 Phase
|
|
130kA / Iimp=50kA
|
210 – 500V
|
275/476V
|
3 Phase
|
|
|
SGD/TSG – Surge Gap Diverter/TSG
|
130 - 140kA / Iimp=50/100kA
|
0.6 – 20kA
|
150 – 440V
|
|
|
DDI – DIN Decoupling Inductor
|
Iline=35 – 63A
|
|
500VAC
200VDC
|
|
|
DSD1150 – DIN Surge Diverter
|
150kA / Iimp= 25kA
|
0.48 – 1.6kV
|
150 – 275VAC
200 – 350VDC
|
|
|
DSD1100
|
100kA / Iimp=10kA
|
480VAC
1.7kVDC
|
150 – 275vAC / 200 - 350VDC
|
|
|
DSD160
|
60kA / Iimp=5kA
|
0.48 – 2kV
|
150 – 440VAC / 200 – 580VDC
|
|
|
DSD140
|
40kA
|
0.48 – 1.8kV
|
150 – 440VAC / 200 – 580VDC
|
|
|
DSD130
|
30kA
|
0.48 – 1.7kV
|
150 – 275VAC / 200 – 350VDC
|
|
|
DSD110
|
10kA
|
0.55 – 1.4kV
|
150 – 440VAC /200 – 580VDC
|
|
|
DSD340, 380
|
40/80kA / Iimp=5/25kA
|
0.85 – 1.7kV
|
275VAC / 350VDC
|
3 Phase
|
|
TDS/TDS50/DAR/TDS SC – TD suppressor & DINLINE Alarm & Relay Surge Counter
|
10 – 80kA
Iimp= 8 – 16kA
|
600 – 960V
|
275 – 340V
|
|
|
TDF – Transient Discriminating Filter
|
20ka (L-N, L-G)
10kA (N-G)
|
250 – 600V
|
170 – 340V
|
1 Phase
|
|
DSF – DINLINE Surge Filter
|
4 – 16kA
|
110 – 750V
|
30 – 275VAC
38VDC
|
1 Phase
|
|
OHA - Overhead Arrester
|
30kA
|
1.2 - 2kV @15kA
|
150 – 440V
|
|
|
LPP – Light Pole Protector
|
40kA
|
1.2 – 1.8kV
|
320 – 550V
|
1 Phase
|
|
UTB – Universal Transient Barrier
|
20kA
|
10 – 480V (L-L)
|
5 – 150VAC
7 – 200VDC
|
|
|
DSD (DC) SIN Surge Diverter
|
20kA
|
19 – 40V (L-L)
|
15 – 28VDC
|
|
|
SLP/HSP/DLT – Subscriber/High Speed Line Protection/Termination
|
20kA ([L+L]-E)
Iline= 0.12 – 1A
|
|
13 – 190V
|
|
|
RJ11 Telephone Line Protection
|
0.5 – 20kA
|
110V (T-R)
500V ([T-R]-G)
|
280V
|
|
|
DEP - Data Equipment Protector
|
|
|
9 – 15VDC
|
|
|
LAN Protector
|
500A
|
23V (L-L)
140V (L-G)
|
Up to 65VDC
|
|
|
CATV - Community Antenna TV Protector
|
5kA
|
90V
|
|
|
|
CCTV - Closed Circuit TV Protector
|
20kA
|
60V
|
|
|
|
LCP – Loadcell Protector
|
300A – signal-shield
10kA – shield-ground
|
30V - signal-ground
15V - signal-signal
90V - shield-ground
|
|
|
|
TEC/IJP – Transient Earth Clamp & Insulated Joint Protector
|
100kA
|
1000V @ 1kV/µs
|
|
|
|
PLF – Power Line Filter
|
20kA
|
50 – 600V
|
275V
|
1 Phase
|
|
MSPD – Multi-socket Protection Device
|
5kA
|
600V
|
275V
|
1Phase
|
|
Model
|
Iline
|
Up
|
Surge Rating
|
Phase/Pole
|
|
PANAMAX MAX 8 – Plug-in Protector
|
15A
|
330V
Telephone – 260V
CATV – 0.7V
Satellite – 27V
|
52kA
|
1 Phase
|
|
PANAMAX MAX 2
|
15A
|
330 – 700v
Telephone – 260V
CATV – 0.7V
|
52kA
|
1 Phase
|
|
PANAMAX MAX ImagePro 20 – Digital Equipment Noise Filter
|
20A
|
330V
Telephone – 260V
LAN – 7V
|
52kA
|
1 Phase
|
|
PANAMAX TowerMAX – Modular Plug-in Protector
|
15A
|
330V
Telephone – 260V
LAN – 7V
T1 – 70V
|
52kA
|
1 Phase
|
For more information and product specifications, please refer to the relevant document link, or contact us on 02 9602 8331.