Novaris Range

The Novaris range includes variety of surge protectors, diverters, filters and arresters available in single and three phase.

The Novaris range includes variety of surge protectors, diverters, filters and arresters available for single and three phase applications.A step by step concept is adopted in the design of surge protectors to ensure maximum safety to high power equipment. The surge protectors are designed to utilise the existing infrastructure (such as the earth grid) to dissipate unexpected spikes and surges (such as those from lightning strikes) to reduce and eliminate damage to sensitive equipment and loads. Below is a table outlining specifications for the Novaris surge protection range. For more detailed specifications, download the Novaris Range document. 

Novaris Range Technical Description


Imax = Maximum Discharge Current (8/20µs) [unless stated otherwise]
U= Voltage Protection Level - @ 3kA (8/20µs) [unless stated otherwise]
Uc = Maximum continuous operating voltage
Iimp= Maximum impulse current (10/350µs) [unless stated otherwise]
Iload=Maximum load current
Model
Imax   /   Iimp    /   Iline
Up
Uc
Phase/Pole
MultiMOV MSB Surge Diverter
100A
800V
275VL-N
1 & 3 Phase
Novaris Range SDN Surge Diverter
50 – 200kA
 800V
275V
1 & 3 Phase
Novaris Range SDD DINsafe Surge Diverter
50 – 100kA
 800V
275VL-N
1 & 3 Phase
Novaris Range SDD2 SINsafe Surge Diverter
10 – 100kA
40 – 400V
81 – 150V
2 Pole
Novaris Range SDPV Surge Diverter  - Photovoltaic
40kA
1600 – 4000V
400 – 1000V
2 Pole
SDH High Voltage Surge Diverter
100 – 200kA
1.6 – 4.8kV
550 – 2000V
1 Phase
SG Spark Gap Arrester
Iimp= 50 – 110kAL-N / Iimp= 150kAN-PE
1.3 – 2.5 KV
255 – 275V
1 & 3 Phase
HSG Hybrid Spark Gap Arrester
Iimp=25kA
 1.1kV
480VL-N
1 & 3 Phase
SSP Single Phase Surge Protector
6.5 – 100kA
 800V
275V
1 Phase
SSP Three Phase Surge Protector
50 – 100kA
 800V
275V
3 Phase
SFH Surge Filters - Iload= 250 – 800A
100 – 200kA
 360V
275V
3 Phase
SFH Surge Filters - Iload=1200 - 2000A
100 – 200kA
360V
275V
3 Phase
SFM Surge Filters - Iload= 40 – 63A
50 – 100kA
 360V
275V
1 & 3 Phase
SFM Surge Filters – Iload= 125A
50 – 100kA
 360V
275V
1 & 3 Phase
SFD Surge Filters - Iload= 2-32A/phase
6.5 – 100kAL-N
Min. 600V
275V
1 Phase
SFD Surge Filters - Iload= 2-32A/phase
50kA
Min. 600V
275V
3Phase
Plug-in Surge Filters - Iload= 10A
50kA
 600V
275V
PP Plug-in Surge Filters  - Iload= 10-15A
19-50kA
 600V
275V
Model
Imax   /   Imp    /   Iline
Up
Uc
Frequency
SL Slimline Signal Line Protectors
10kA
Impulse Voltage: 8 - 235V (1.25/50µs)
7-200VDC
5-140VAC
0.25 – 20MHz
10kA
Impulse Voltage: 15 - 50V (1.25/50µs)
8 – 34VDC
6 – 24VAC
0.25 – 20MHz
SSP Slimline Series Surge Protectors
3.6 – 9.6kA
26 – 250V @ 5kV (10/700µs)
11 – 130V
100kHZ
SLM (multiline Protectors)
20kA
8 - 235V
5 – 140vV
250kHz/25MHz
RS Protectors (Serial Port Protectors)
250A
14 - 40V
8.2 - 36V
LCP (Load Cell Protector) 5 – 6.5A
250A
18 – 36V
CCTC Protection
CL Coaxial CCTV Protectors (200mA)
20kA
14 – 40V @ 5kV (10/700µs)
8.2 – 36V
20MHz
SFD Combined Protectors
Power
2 – 6.5kA
50 - 750V
30 – 275V
1 Phase
Signal
20kA
14V
8.2V
20MHz
SLD Hardwired Protection
20kA
130V @1kV/µs
7 – 200VDC
5 – 46VAC
0.25 - 20MHz
LAN Protection
RJ45 UTP Network Protectors (terminal)
Signal
10kA
< 20V @ 5kV (10/700µs)
6V
250MHz
Power
230V
Telephone Protection
KP Krone-LSA MDF-1 Pair/10 Pair
10kA
30 - 150V @ 5kV (10/700µs)
200V
20MHz
Modular Plug (RJ Protection)
10 – 50kA
30 - 150V
200V
20MHz
Coaxial Protection (RF Equipment Protection)
Gas Discharge Surge Protector
Up to 3GHz
20kA
650V - 1.3kV
90 – 600V
3GHz
Up to 6GHz
650 - 820V
6GHz
Tuned Stub Surge Protectors
50kA
 20V
0.4 – 3GHz
Model
Imax
Power Rating
Spark Over voltage
High Power Surge Protectors
100kA
>50kW
2.6kV @ 2mm gap

 


For more information and product specifications, please refer to the relevant document link, or contact us on 02 9602 8331 or follow us on Facebook to stay up to date and receive regular updates.

Related Documents

Enquire about this product